Clean Agent Fire Suppression

An overview of Clean Agent Fire Suppression range

 

 

 

Clean Agent Fire Extinguishing System 

 

Our clean agent fire extinguishing system is today’s sustainable clean agent solution. It utilizes an extinguishing medium that is suited to protect high-value assets in areas that may be normally occupied, in locations where clean-up of other agents is problematic, when storage space for a fire suppression agent is restricted, or when an electrically non-conductive agent is required. 

Features & Benefits 

 

Our Clean Agent Fire Suppression range has a whole host of features and benefits, making it the ideal solution for a variety of environments.

 

Fully Compliant 

 

Listed by UL (Underwriters Laboratories), FM Approved and fully compliant to NFPA 2001  

 

Integration

 

Combines with Hochiki’s conventional & addressable releasing fire alarm control panel and devices to offer a complete system

 

 

Environmentally Friendly 

 

Zero Ozone Depletion Potential (ODP), short atmospheric lifetime

 

 

 

 

Clean Agent Fire Suppression  

 

Our clean agent fire suppression (SG-227ea / SG-FK5112) utilizes the extinguishing medium (HFC-227ea / FK-5-1-12). HFC-227ea / FK-5-1-12 is a clear, colorless, and low odor agent and is stored as a liquid in cylinder assemblies designed for the application and charged to a fill density of 0.5kg/L to 1kg/L. Available with 25 bar, 42 bar, and 50 bar in a wide range of cylinder size options. 

 

 

 

 

Components

 

Components for our clean agent fire extinguishing system include discharge valves, actuators (manual, electromagnetic & pneumatic), pressure gauges, discharge hoses, valve outlet adaptors, check valves and pilot line hoses. 

 

 

 

 

HCVR-3 Conventional Fire Alarm & Releasing Panel

 

HCVR-3 is a 3 zone conventional releasing fire alarm control panel that is UL Listed and FM Approved for releasing. It can be configured to activate releasing by a single zone or combination of any two zones. 

 

 

 

 

Hochiki’s Devices 

 

Hochiki offers both addressable and conventional range of products. Our wide range of products includes smoke/multi detectors, pull stations, and audio & visual devices.  

HCVR-3

Conventional Fire Alarm Control Panel

HCVR-3 is a 3 zone conventional releasing fire alarm control panel that is UL Listed and FM Approved for releasing. 

 

View HCVR-3

SG-227ea

Clean Agent Fire Suppression

SG-227ea is a Clean Agent Fire Suppression. The extinguishing medium (HFC-227ea) is a clear, colorless, and low odor agent. 

View SG-227ea

SG-FK5112

Clean Agent Fire Suppression

SG-FK5112 is a Clean Agent Fire Suppression. The extinguishing medium (FK-5-1-12) is a clear, colorless, and low odor agent. 

View SG-FK5112

Check Valve

Clean Agent Fire Suppression

The check valve is used to prevent agent loss when discharging while the cylinder is removed for maintenance. 

 

View Check Valve 

Cylinder Assembly (Seamless)

Clean Agent Fire Suppression

The cylinder assembly (seamless) - 10L-140L capacity is used to contain the agent in a pressurized condition. 

 

View Cylinder Assembly (Seamless) 

Cylinder Assembly (Welded)

Clean Agent Fire Suppression

The cylinder assembly (welded) - 9L-369L capacity is used to contain the agent in a pressurized condition. 

 

View Cylinder Assembly (Welded) Now 

Cylinder Mounting Strap

Clean Agent Fire Suppression

The cylinder mounting strap is used for securing the cylinder in a vertical position. 

 

View Cylinder Mounting Strap 

Discharge Hose

Clean Agent Fire Suppression

The discharge hose is used for carrying the agent from the cylinder to the outlet. 

 

View Discharge Hose 

Discharge Nozzle

Clean Agent Fire Suppression

The discharge nozzle is for the 360° release of the agent (8 holes). or (16 holes). 

 

View Discharge Nozzle 

Discharge Valve Assembly

Clean Agent Fire Suppression

The discharge valve assembly is in charge of the release of the agent from the cylinder to the manifold. 

 

View Discharge Valve Assembly 

Electric & Manual Actuator

Clean Agent Fire Suppression

The electric & manual actuator is to electrically or manually activate the system. 

 

View Electric & Manual Actuator 

Pilot Line Hose

Clean Agent Fire Suppression

The pilot line hose is used for connecting pneumatic actuators from the master cylinder to the slave cylinder. 

 

View Pilot Line Hose 

Pneumatic Actuator

Clean Agent Fire Suppression

The pneumatic actuator is for actuating the release of the agent in the slave cylinder. 

 

View Pneumatic Actuator 

Pressure Gauge

Clean Agent Fire Suppression

The pressure gauge is an indicator of the pressure of the cylinder. 

 

View Pressure Gauge 

Pressure Gauge w/ Low Pressure Switch

Clean Agent Fire Suppression

The pressure gauge w/ low pressure switch is an indicator for the pressure of the cylinder with an alert for low pressure. 

 

VIew Pressure Gauge w/ Low Pressure Switch 

Valve Outlet Adaptor

Clean Agent Fire Suppression

The valve outlet adaptor is for the direct connection of the cylinder valve to the distribution piping. 

 

View Valve Outlet Adaptor 

Cylinder Assembly (Welded Dot)

Clean Agent Fire Suppression

The cylinder assembly (welded dot) - 29L-369L capacity is used to contain the agent in a pressurized condition.

 

View Cylinder Assembly (Welded Dot)

Evacuate Flashing Light

Clean Agent Fire Suppression

The “EVACUATE” flashing type warning light is the visual alarm that is used to warn personnel inside the protected room that the fire detection agent release control panel of the extinguishing system has been activated.

View Evacuate Flashing Light 

Gas Discharge Flashing Light

Clean Agent Fire Suppression

The “GAS DISCHARGE” flashing type warning light is the visual alarm that is used to warn personnel outside the protected room that the fire detection agent release control panel of the extinguishing system has been activated. 

View Gas Discharge Flashing Light 

Entrance Door Warning Light

Clean Agent Fire Suppression

The entrance warning sign is to be located at the door outside the protected room. 

View Entrance Door Warning Light 

Exit Door Warning Sign

Clean Agent Fire Suppression

The exit warning sign is to be located at the door inside the protected room. 

View Exit Door Warning Sign 

Enquire now